Series 3200 Nuclear Service Qualified Pressure Transmitters

  • Transmitters meet the requirements of nuclear safety-related service for Boiling Water Reactors (BWR) and Pressurized Water Reactors (PWR)
  • 3200 series transmitters have been tested according to the standards of IEEE 323, 1974, and IEEE 344, 1975, and meet the requirements of 10CFR50 Appendix B, reporting requirements 10CFR21 as well as NQA-1 Quality Program
  • qualification according to KTA 3505
  • sputtered thin film strain gage sensor technology with differential resistance measurement like 3000 series
  • 10 year qualified life at 115°F operating temperature
  • non-interactive Zero and Span adjustment, both customer specified calibration and field calibration adjustments possible
  • sensor and DC electronics in fully welded, hermetically sealed 316SST housing with 5 year warranty
  • micro head with Durock silicone ceramics insulation tested for tightness up to 1088 bars
  • high accuracy </=+/-0,25% of calibrated span (incl. linearity, repeatability, hystersis
  • response time adjustable at factory from <24 to <300 ms (damping)
  • frequently qualified and used as redundant system (resistive vs. capacitive measuring technology) for prevention of common mode errors
  • qualified to 5,5 x 107 RADs TID gama radiation
  • application and successful audits by NCR, NUPIC, MCCR, TVA, German TUEV and others 


 

PA/PG3200 - Gage and Absolute Pressure Transmitter

    Datasheet PG3200


 

PD/PDH3200 - Differential Pressure Transmitter

    Datasheet PD/PDH3200


 

DR3200 - Draft Range Differential Pressure Transmitter


 

PD3218 - Remote Seal / Capillary Differential Pressure


 

Data Sheets upon special request